Quick Answer

A 5/8" Drop-In Anchor needs a 7/8" pilot hole, drilled to 2" minimum, with 2-1/2" minimum embedment, torqued to Set with setting tool; 30 ft-lbs max on the bolt.

Pilot Hole
7/8"
Embedment
2-1/2" minimum (sits flush with surface)
Torque
Set with setting tool; 30 ft-lbs max on the bolt
Safe Load
831 lbs

Where to Buy

As an Amazon Associate, BuildToolHQ earns from qualifying purchases. Specifications are for guidance only — always verify against the anchor manufacturer's ICC-ES ESR report and local building codes.

Full Specification

Type
Drop-In Anchor
Diameter
5/8"
Available Lengths
1-5/8" shell
Pilot Hole Diameter
7/8"
Pilot Hole Depth
2" minimum
Embedment Depth
2-1/2" minimum (sits flush with surface)
Recommended Torque
Set with setting tool; 30 ft-lbs max on the bolt
Compatible Substrates
Solid concrete only
Load Rating
831 lbs tension safe working load — Ultimate: 3,323 lbs tension — Ultimate values in 2000 PSI concrete (Confast). Allowable calculated at the industry-standard 4:1 safety factor. — Confast publishes no shear value for drop-in anchors.
Material
Zinc-plated steel, Stainless steel
Removable
No — permanent installation

Best For

  • Heavy industrial overhead equipment
  • Crane rail anchoring
  • Large mechanical pipe hangers
  • Structural suspended connections

Not For

  • Hollow block
  • Brick
  • Residential applications
  • Any use without engineer specification

How a Drop-In Anchor Grips

A drop-in anchor is an internally threaded steel body that expands when a setting tool drives its internal plug outward against the hole wall. It cannot grip without being set: dropping it in the hole and threading a bolt in is not an installation, which is why the setting tool is a requirement, not an accessory.

Installation Tips

1.Requires SDS-Max rotary hammer for 7/8" hole — SDS-Plus struggles at this diameter
2.Setting tool must be rated for 5/8" drop-ins — do not use smaller setting tools
3.Engineer specification required for all overhead applications
4.Used with 5/8-11 threaded rod — standard for heavy structural suspended systems
5.Inspect setting tool condition before use — worn tools lead to under-set anchors

Frequently Asked Questions

What size drill bit does a 5/8" Drop-In Anchor need?

Use a 7/8" carbide masonry bit, drilled to 2" minimum.

How much weight can a 5/8" Drop-In Anchor hold?

831 lbs tension safe working load. Actual capacity depends on base material strength and embedment — verify against the manufacturer's ICC-ES ESR data for structural work.

How deep should the hole be?

Drill to 2" minimum. Minimum embedment for this anchor is 2-1/2" minimum.

How much should a 5/8" Drop-In Anchor be torqued?

Tighten to Set with setting tool; 30 ft-lbs max on the bolt. Over-torquing is a common cause of anchor failure.

Can a Drop-In Anchor be removed after installation?

No — this is a permanent installation; the anchor body stays in the hole.