Lag Shield

3/8" Lag Shield Anchor — Complete Specifications

Pilot hole size, embedment depth, torque values, load ratings, and installation guide per ACI 318-19.

Fastener Specification — ACI 318-19

Diameter
3/8"
Pilot Hole Size
5/8"
Pilot Hole Depth
1-5/8" (short) / 2-1/4" (long)
Embedment Depth
1-1/4" (short) / 2" (long)
Torque Value
Hand-tight + 1/4 turn
Max Load
600 lbs (tension), 800 lbs (shear)
Material
Zinc-plated lead alloy
Removable
Yes
Available Lengths
Short (1-1/4"), Long (2")

Substrates: Concrete, Brick, Solid block

Best for

  • Deck ledger boards
  • Heavy wood framing to concrete
  • Gate post anchoring
  • Pergola post bases

Not suitable for

  • Hollow block
  • High seismic zones
  • Structural column bases

Installation tips

  • 1.Drill a 5/8" hole for a 3/8" lag shield — correct oversize is critical
  • 2.Tap shield flush with or slightly below the surface with a hammer
  • 3.Drive a 3/8" lag screw to expand — stop when resistance increases significantly
  • 4.Long shields recommended for older or softer concrete and brick

As an Amazon Associate, BuildToolHQ earns from qualifying purchases. Specifications are for guidance only — always verify against the anchor manufacturer's ICC-ES ESR report and local building codes.